Programming - Asset Management
69
RMS Enterprise - NetLinx Programmer’s Guide
Asset Parameter Set Value Functions (Cont.)
RmsAssetParameter
SetValueNumber
Description: This function is used to set a new asset parameter value to the RMS server immediately.
This function will set an asset parameter of data type: NUMBER
Arguments:
CHAR assetClientKey[] - asset client key
CHAR parameterKey[] - monitored parameter key
SLONG parameterValue - monitored parameter value
Returns: 1 if call was successful; 0 if call was unsuccessful
Syntax:
DEFINE_FUNCTION CHAR RmsAssetParameterSetValueNumber(CHAR assetClientKey[],
CHAR parameterKey[],
SLONG parameterValue)
{
RETURN RmsAssetParameterSetValue(assetClientKey,
parameterKey,
ITOA(parameterValue));
}
RmsAssetParameter
SetValueDecimal
Description: This function is used to set a new asset parameter value to the RMS server immediately.
This function will set an asset parameter of data type: DECIMAL
Arguments:
CHAR assetClientKey[] - asset client key
CHAR parameterKey[] - monitored parameter key
DOUBLE parameterValue - monitored parameter value
Returns: 1 if call was successful; 0 if call was unsuccessful
Syntax:
DEFINE_FUNCTION CHAR RmsAssetParameterSetValueDecimal(CHAR assetClientKey[],
CHAR parameterKey[],
DOUBLE parameterValue)
{
RETURN RmsAssetParameterSetValue(assetClientKey,
parameterKey,
FTOA(parameterValue));
}
RmsAssetParameter
SetValueLevel
Description: This function is used to set a new asset parameter value to the RMS server immediately.
This function will set an asset parameter of data type: LEVEL
Arguments:
CHAR assetClientKey[] - asset client key
CHAR parameterKey[] - monitored parameter key
SLONG parameterValue - monitored parameter value
Returns: 1 if call was successful; 0 if call was unsuccessful
Syntax:
DEFINE_FUNCTION CHAR RmsAssetParameterSetValueLevel (CHAR assetClientKey[],
CHAR parameterKey[],
SLONG parameterValue)
{
RETURN RmsAssetParameterSetValue(assetClientKey,
parameterKey,
ITOA(parameterValue));
}
Vedere la pagina 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 219 220

Commenti su questo manuale

Nessun commento

Vista Caméras de sécurité manuels d'utilisation

La liste de Vista Caméras de sécurité produits contient 6 manuels d'utilisation pour les modèles 4. Tous les guides d'utilisation en format pdf peuvent être téléchargés ou consultés en ligne.

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
Series 3 CCD Cameras
Manuel de l'utilisateur       Vista Series 3 CCD Cameras User's Manual, 52 pages
VBC-800NI30-WC
Manuel de l'utilisateur   Vista VBC-800NI30-WC User's Manual, 1 pages
VIP Kit2 VK2-ENCODER
Manuel de l'utilisateur   Vista VIP Kit2 VK2-ENCODER User manual, 72 pages
Manuel de l'utilisateur   Vista VIP Kit2 VK2-ENCODER User manual, 104 pages
Manuel de l'utilisateur   Vista VIP Kit2 VK2-ENCODER User manual, 68 pages
VPC9030
Manuel de l'utilisateur   Vista VPC9030 User's Manual, 12 pages