Installation
9
UPC20+ Universal Power Controller
UPC20+ Control Mode Functions for Inputs 1 and 2 (Cont.)
Control
Mode
S2 Switch
Setting
R8 Motor
Time Delay
Pot
Input 1
(P2, pin 5-to GND)
Input 2
(P2, pin-6 to GND)
Power, 2
Button
On, Off, Off, On Minimum Push 1 = load 1 "on"
Release 1 = load 1 "still
on"
Push 2 = load 2 "on"
Release 2 = load 2 "still on"
Maximum Push 1 = load 1 "on"
Release 1 = load 1 "still
on"
Note: Both loads can be
On at the same time.
Push 2 = load 2 "on"
Release 2 = load 2 "still on"
Power,
Momentary
#1, Latch-
ing #2
On, Off, On, On Minimum Push 1 = load 1 "on"
Release 1 = load 1 "off"
Push 2 = load 2 = "on"
Release 2 = load 2 "still on"
Push 2 again = load 2 "off"
Release 2 again = load 2
"still off"
Maximum Push 1 = load 1 "on"
Release 1 = load 1 "off"
Note: Delay time does not
effect loads.
Push 2 = load 2 = "on"
Release 2 = load 2 "still on"
Push 2 again = load 2 "off"
Release 2 again = load 2
"still off"
Power,
Momentary
#1, Latch-
ing #2
Minimum Push 1 = load 1 "on"
Release 1 = load 1 "still
on"
Push 1 again = load 1 "off"
Release 1 again = load 1
"still off"
Push 2 = load 2 "on"
Release 2 = load 2 "off"
Maximum Push 1 = load 1 "on"
Release 1 = load 1 "still
on"
Push 1 again = load 1 "off"
Release 1 again = load 1
"still off"
Note: Delay time does not
affect loads.
Push 2 = load 2 "on"
Release 2 = load 2 "off"
UPC20+ Control Mode Functions for Inputs 3 and 4
Control Mode S2 Switch
Setting
R8 Motor
Time Delay
Pot
Input 1
(P2, pin 5-to GND)
Input 2
(P2, pin-6 to GND)
Motor, Single But-
ton
On, On, Off, On Minimum Not used Not used
Minimum Not used Not used
Motor, 2/3 Button Off, Off, Off, On Minimum Not used Not used
Maximum Not used Not used
Motor, Momentary Off, On, Off, On Minimum Not used Not used
Maximum Not used Not used
Power, Momentary On, On, On, On Minimum Not used Not used
Maximum Not used Not used
Power, Latching Off, On, On, On Minimum Not used Not used
Maximum Not used Not used
Vedere la pagina 14