NXI NetLinx Integrated Controller
3
NXI NetLinx Integrated Controller (No Master)
NXI Specifications (Cont.)
Rear Panel Components (Cont.)
Relay port
(Port #7)
Three 8-pin (male) relay connectors (normally open) that support up to 12 indepen-
dent external relay devices. Each relay can switch up to 24 VDC or 28 VAC @ 1 A.
Channel range = 1-12
IR/Serial ports
(Ports #8-15)
Two 8-pin (male) connectors that support IR or serial (wired) IR control.
The 8 IR/Serial control ports support high-frequency carriers up to 1.14 MHz.
Channel range = 1-32,767
Channels 1-253: = IR commands
Channel 254: = PowerFail (used with 'PON' and 'POF' commands)
Channel 255: = Power status (when IOLink is set)
I/O port
(Port #16)
8-channel I/O port for contact closure, 0-5 VDC voltage sensing, or interactive power
sensing for IR ports.
The 10-pin (male) connector has inputs that detect 0-1.5 VDC (low) as a Push, and
3.5-5 VDC (high) as a Release.
When used as an input, each of the eight I/O ports act as a switch to ground and
are rated at 200 mA @ 12 VDC.
Channel range = 1-8
Certifications FCC Part 15 Class B, CE, and IEC 60950
Included accessories 4 CC-NIRC emitters
Metal tab strips for commoning adjacent relays
Rack-mount brackets adapt for rack, wall, or shelf mounting
NetLinx faceplate
Optional accessories 12 VDC power supply
CC-N232 RS-232/422 cables
CC-NIRC IR cables
CC-NREL Relay cables