Installation Sheet
RDC-PDC Control Card, Dual or Three Phase
(120 or 240 VAC)
The RDC-PDC Control Card module controls up to six dimmable channels
with six satellite connectors (for RDM series dimmer or switching modules).
The RDC-PDC is controlled by AXlink, PROlink, or by dry contact closures.
The RDC-PDC is designed for use with Radia enclosures, in a modular dig-
ital dimming system. The module's 120 and 240 VAC ratings are CE, UL,
and C-UL approved.
RDC-PDC UL and C-UL Ratings:
Control Input:
AXlink
PROlink
Eight dry closures
Control Output:
Six control ports
Max. total control current at 300 mA
Power Inputs:
Line 1 (channel 1 and 4)
Line 2 A (channel 5)
Line 2B (channel 2)
Line 3 (channel 3 and 6)
Neutral
Specifications:
Dimensions (HW): 10.0" x 2.75" (254.0 mm x 69.85 mm)
12 VDC power (optional)
Torque terminals to 20 in-lbs. (2.3 N/M)
Max. wire size: 10 AWG
Wire stripping length: 0.28" (7 mm)
Weight: 1.5 lbs. (0.68 kg)
Power consumption: 50 mA @ 120 VAC
25 mA @ 240 VAC
Button/Jumper Information:
RESET button: By pressing the RESET button, located on the RDC-
PDC circuit board, it is possible to restart the processor without having
to power-down the unit or disconnect AXlink or PROlink. RESET does
not affect saved presets or curve settings.
MEMORY PROTECT on/off jumper: The MEMORY PROTECT
jumper is set to Off by default. To protect saved curve settings and pre-
sets from accidental recording, put the jumper in the On position.
Caution: Pre-Installation Notes
All Class 1 wiring must be connected to proper terminals.
All control wiring must be connected to proper terminals.
Disconnect power while installing or connecting the unit.
Keep the top and bottom air vents clear at all times.
Test loads for shorts before connecting.
Use low-voltage wires with a 300 volt rating or greater.
Use field-installed copper conductors.
All electrical ratings are for continuous duty.
For indoor use only.
AC lighting loads only.
Connecting RDM Series to the AMX Lighting Master
Connecting AXlink
Connect the 4-pin captive-wire AXlink connector from the RDC-PDC to the
Central Controller for AXlink control of the dimming system.
Connecting PROlink:
Connect the orange 4-pin captive-wire PROlink connector from the RDC-
PDC to a PRO-DP8 PROlink wall panel.
FIG. 1 RDC-PDC control card
Line inputs
(factory wired)
Mounting
points
Reset button
Memory Protect
jumper
AXlink connector
PROlink connector
LED indicators
Control ports
Dry closure
contacts
AXlink DIP
switch
PROlink DIP
switch
FIG. 2 Connecting RDM series
FIG. 3 AXlink wiring
FIG. 4 PROlink wiring
Pin 4 (GND)
Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)
RDC-PDC 4-pin module connector
4-pin plug from a RDM series module
Note: The 4-pin plugs from the module
connector to the 4-pin connector on the
master (black plug cover facing up).
PWR
AXP
AXM
GND
PWR
AXP
AXM
GND
Central
RDC-PDC
Controller
(optional)
PRO-DP8 Pack 1 Pack 2
+12
PR+
PR-
GND
+12
PR+
PR-
GND
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - Installation Sheet

Installation SheetRDC-PDC Control Card, Dual or Three Phase(120 or 240 VAC)The RDC-PDC Control Card module controls up to six dimmable channels with s

Pagina 2 - Connecting Dry Closures

2 RDC-PDC Control Card, Dual or Three PhaseConnecting Dry ClosuresUse the 8 (+ common) dry closures with a WPD8 eight-button wall panel. Each conta

Pagina 3

RDC-PDC Control Card, Dual or Three Phase 3FIG. 8 Method BFIG. 9 Method CFIG. 10 Method DMethod BRDC-PDC/120 3-phase, 6 switchesMethod CThree phase

Pagina 4

AMX Corporation reserves the right to alter specifications without notice at any time. For full warranty information, refer to the AMX Instruction Man